--/***************************************************************************/ --/** */ --/** AKCP, Ltd */ --/** Proprietary and Confidential Information */ --/** */ --/** This material contains, and is part of a computer software program */ --/** which is, proprietary and confidential information owned by AKCP,Ltd */ --/** The program, including this material, */ --/** may not be duplicated, disclosed or reproduced in whole or in part for */ --/** any purpose without the express written authorization of AKCP, Ltd */ --/** All authorized reproductions must be marked with this legend. */ --/** */ --/** */ --/** Copyright (c) 1994-2007 */ --/** AKCP, Ltd */ --/** All rights reserved */ --/** */ --/***************************************************************************/ --/***************************************************************************/ --/** */ --/** This MIB is a superset which includes all of the features in the */ --/** sensorProbe family. Some features may not be implemented in certain */ --/** models. */ --/** */ --/***************************************************************************/ SPAGENT-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; akcp OBJECT IDENTIFIER ::= { enterprises 3854 } sensorProbe OBJECT IDENTIFIER ::= { akcp 1 } spSummary OBJECT IDENTIFIER ::= { sensorProbe 1 } spStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), warning(3), critical(4), sensorError(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this sensorProbe. The status of the sensorProbe is the worst status of all the sensors under the control of this sensorProbe." ::= { spSummary 2 } spManufName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The manufacturers name" ::= { spSummary 6 } spHelpUrl OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The URL of the web based help" ::= { spSummary 7 } spProductName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The product name" ::= { spSummary 8 } spSensor OBJECT IDENTIFIER ::= { sensorProbe 2 } sensorProbeDetail OBJECT IDENTIFIER ::= { spSensor 2 } sensorProbeEntry OBJECT IDENTIFIER ::= { sensorProbeDetail 1 } sensorProbeHost OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Host of this sensor, this is the IP address" ::= { sensorProbeEntry 1 } sensorProbeUseDHCP OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To use DHCP enter a 1, to use a static IP address enter a 2" ::= { sensorProbeEntry 2 } sensorProbeMAC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of this system" ::= { sensorProbeEntry 3 } sensorProbeSetCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The sensorProbe community string used for snmp Sets" ::= { sensorProbeEntry 4 } sensorProbeGetCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The sensorProbe community string used for snmp Gets" ::= { sensorProbeEntry 5 } sensorProbeTempTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorProbeTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor." ::= { sensorProbeEntry 16 } sensorProbeTempEntry OBJECT-TYPE SYNTAX SensorProbeTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorProbeTempEntry Table" INDEX { sensorProbeTempIndex } ::= { sensorProbeTempTable 1 } SensorProbeTempEntry ::= SEQUENCE { sensorProbeTempDescription DisplayString, sensorProbeTempLocation DisplayString, sensorProbeTempDegree INTEGER, sensorProbeTempStatus INTEGER, sensorProbeTempOnline INTEGER, sensorProbeTempGoOnline INTEGER, sensorProbeTempHighWarning INTEGER, sensorProbeTempHighCritical INTEGER, sensorProbeTempLowWarning INTEGER, sensorProbeTempLowCritical INTEGER, sensorProbeTempRearm INTEGER, sensorProbeTempDegreeType INTEGER, sensorProbeTempSensorType INTEGER, sensorProbeTempDegreeRaw INTEGER, sensorProbeTempEmailTrapLimit INTEGER, sensorProbeTempEmailTrapSchedule DisplayString, sensorProbeTempEmailTrapInterval INTEGER, sensorProbeTempSendNormalTrap INTEGER, sensorProbeTempDelayError INTEGER, sensorProbeTempDelayNormal INTEGER, sensorProbeTempIndex INTEGER, sensorProbeTempRelayCycleTime INTEGER, sensorProbeTempRelayOnPort INTEGER, sensorProbeTempRelayActiveStatus INTEGER, sensorProbeTempRelayAction INTEGER, sensorProbeTempEmailInterval INTEGER, sensorProbeTempIndexCount INTEGER, sensorProbeTempOffset INTEGER, sensorProbeTempSirenCycleTime INTEGER, sensorProbeTempSirenOnPort INTEGER, sensorProbeTempSirenActiveStatus INTEGER, sensorProbeTempSirenAction INTEGER, sensorProbeTempAcknowledgement INTEGER, sensorProbeTempSirenDelayAlarm INTEGER } sensorProbeTempDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorProbeTempEntry 1 } sensorProbeTempLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this sensor" ::= { sensorProbeTempEntry 2 } sensorProbeTempDegree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The degrees in this sensor" ::= { sensorProbeTempEntry 3 } sensorProbeTempStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorProbeTempEntry 4 } sensorProbeTempOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { sensorProbeTempEntry 5 } sensorProbeTempGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { sensorProbeTempEntry 6 } sensorProbeTempHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorProbeTempEntry 7 } sensorProbeTempHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorProbeTempEntry 8 } sensorProbeTempLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorProbeTempEntry 9 } sensorProbeTempLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorProbeTempEntry 10 } sensorProbeTempRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorProbeTempEntry 11 } sensorProbeTempDegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { sensorProbeTempEntry 12 } sensorProbeTempSensorType OBJECT-TYPE SYNTAX INTEGER { type1(0), type2(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of temperture sensor" ::= { sensorProbeTempEntry 13 } sensorProbeTempDegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SP Only: The raw degree data from the temperature sensor, slightly higher resolution" ::= { sensorProbeTempEntry 14 } sensorProbeTempEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { sensorProbeTempEntry 16 } sensorProbeTempEmailTrapSchedule OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Email/trap limit schedule for this sensor" ::= { sensorProbeTempEntry 17 } sensorProbeTempEmailTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)." ::= { sensorProbeTempEntry 18 } sensorProbeTempSendNormalTrap OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email/trap when sensor goes to normal" ::= { sensorProbeTempEntry 19 } sensorProbeTempDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorProbeTempEntry 20 } sensorProbeTempDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorProbeTempEntry 21 } sensorProbeTempIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the temperature sensor table" ::= { sensorProbeTempEntry 22 } sensorProbeTempRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { sensorProbeTempEntry 23 } sensorProbeTempRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { sensorProbeTempEntry 24 } sensorProbeTempRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highCritical(4), highWarning(3), lowCritical(6), lowWarning(5), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { sensorProbeTempEntry 25 } sensorProbeTempRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { sensorProbeTempEntry 26 } sensorProbeTempEmailInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Minimum time between each email (can be from 0 to 60 minutes)" ::= { sensorProbeTempEntry 27 } sensorProbeTempIndexCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Temperature sensor online" ::= { sensorProbeTempEntry 28 } sensorProbeTempOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Offset reading" ::= { sensorProbeTempEntry 29 } sensorProbeTempSirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { sensorProbeTempEntry 30 } sensorProbeTempSirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { sensorProbeTempEntry 31 } sensorProbeTempSirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highCritical(4), highWarning(3), lowCritical(6), lowWarning(5), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { sensorProbeTempEntry 32 } sensorProbeTempSirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { sensorProbeTempEntry 33 } sensorProbeTempAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Linux Version Only: Acknowledged sensor error and stop notification" ::= { sensorProbeTempEntry 34 } sensorProbeTempSirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Linux Version Only: Siren delay in seconds before start Alarm." ::= { sensorProbeTempEntry 35 } sensorProbeHumidityTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorProbeHumidityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Humidity Sensor in the SensorArray. Each row in the table contains data for a different Humidity Sensor." ::= { sensorProbeEntry 17 } sensorProbeHumidityEntry OBJECT-TYPE SYNTAX SensorProbeHumidityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorProbeHumidityEntry Table" INDEX { sensorProbeHumidityIndex } ::= { sensorProbeHumidityTable 1 } SensorProbeHumidityEntry ::= SEQUENCE { sensorProbeHumidityDescription DisplayString, sensorProbeHumidityLocation DisplayString, sensorProbeHumidityPercent INTEGER, sensorProbeHumidityStatus INTEGER, sensorProbeHumidityOnline INTEGER, sensorProbeHumidityGoOnline INTEGER, sensorProbeHumidityHighWarning INTEGER, sensorProbeHumidityHighCritical INTEGER, sensorProbeHumidityLowWarning INTEGER, sensorProbeHumidityLowCritical INTEGER, sensorProbeHumidityRearm INTEGER, sensorProbeHumidityRaw INTEGER, sensorProbeHumidityLowVoltage INTEGER, sensorProbeHumidityHighVoltage INTEGER, sensorProbeHumidityEmailTrapLimit INTEGER, sensorProbeHumidityEmailTrapSchedule DisplayString, sensorProbeHumidityEmailTrapInterval INTEGER, sensorProbeHumiditySendNormalTrap INTEGER, sensorProbeHumidityDelayError INTEGER, sensorProbeHumidityDelayNormal INTEGER, sensorProbeHumidityIndex INTEGER, sensorProbeHumidityAtoDAmountMaxVoltage INTEGER, sensorProbeHumidityAtoDAmountBaseVoltage INTEGER, sensorProbeHumidityAtoDTypeUnit INTEGER, sensorProbeHumidityDcUnit DisplayString, sensorProbeHumidityAtoDJumper INTEGER, sensorProbeHumidityRelayCycleTime INTEGER, sensorProbeHumidityRelayOnPort INTEGER, sensorProbeHumidityRelayActiveStatus INTEGER, sensorProbeHumidityRelayAction INTEGER, sensorProbeHumidityEmailInterval INTEGER, sensorProbeHumidity4to20mAUnit DisplayString, sensorProbeHumidityIndexCount INTEGER, sensorProbeHumidityOffset INTEGER, sensorProbeHumiditySirenCycleTime INTEGER, sensorProbeHumiditySirenOnPort INTEGER, sensorProbeHumiditySirenActiveStatus INTEGER, sensorProbeHumiditySirenAction INTEGER, sensorProbeHumidityAcknowledgement INTEGER, sensorProbeHumiditySirenDelayAlarm INTEGER } sensorProbeHumidityDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorProbeHumidityEntry 1 } sensorProbeHumidityLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this sensor" ::= { sensorProbeHumidityEntry 2 } sensorProbeHumidityPercent OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The relative humidity percentage measured by this sensor" ::= { sensorProbeHumidityEntry 3 } sensorProbeHumidityStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorProbeHumidityEntry 4 } sensorProbeHumidityOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { sensorProbeHumidityEntry 5 } sensorProbeHumidityGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { sensorProbeHumidityEntry 6 } sensorProbeHumidityHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative humidity this sensor measures before it sends a warning" ::= { sensorProbeHumidityEntry 7 } sensorProbeHumidityHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative humidity this sensor measures before it becomes critical" ::= { sensorProbeHumidityEntry 8 } sensorProbeHumidityLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative humidity this sensor measures before it sends a warning" ::= { sensorProbeHumidityEntry 9 } sensorProbeHumidityLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative humidity this sensor measures before it becomes critical" ::= { sensorProbeHumidityEntry 10 } sensorProbeHumidityRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The percent relative humidity to rearm the status. For example if status goes from normal to warning, the humidity must go down spAnalogueRearm below warning before the status goes to normal" ::= { sensorProbeHumidityEntry 11 } sensorProbeHumidityRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { sensorProbeHumidityEntry 13 } sensorProbeHumidityLowVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The low voltage range for use in AtoD conversion." ::= { sensorProbeHumidityEntry 14 } sensorProbeHumidityHighVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The high voltage range for use in AtoD conversion." ::= { sensorProbeHumidityEntry 15 } sensorProbeHumidityEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { sensorProbeHumidityEntry 17 } sensorProbeHumidityEmailTrapSchedule OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Email/trap limit schedule for this sensor" ::= { sensorProbeHumidityEntry 18 } sensorProbeHumidityEmailTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)" ::= { sensorProbeHumidityEntry 19 } sensorProbeHumiditySendNormalTrap OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email/trap when sensor goes to normal" ::= { sensorProbeHumidityEntry 20 } sensorProbeHumidityDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorProbeHumidityEntry 21 } sensorProbeHumidityDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorProbeHumidityEntry 22 } sensorProbeHumidityIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Humidity sensor table" ::= { sensorProbeHumidityEntry 23 } sensorProbeHumidityAtoDAmountMaxVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum scale of DC voltage conversion." ::= { sensorProbeHumidityEntry 24 } sensorProbeHumidityAtoDAmountBaseVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base scale of DC voltage conversion." ::= { sensorProbeHumidityEntry 25 } sensorProbeHumidityAtoDTypeUnit OBJECT-TYPE SYNTAX INTEGER { absolute(1), percent(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of scale for use in DC voltage conversion." ::= { sensorProbeHumidityEntry 26 } sensorProbeHumidityDcUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Display unit in DC voltage conversion." ::= { sensorProbeHumidityEntry 27 } sensorProbeHumidityAtoDJumper OBJECT-TYPE SYNTAX INTEGER { jumperAt60(600), jumperAt40(400), jumperAt30(300), jumperAtAt20(200), jumperAt10(100), jumperAt-10(-100), jumperAt-20(-200), jumperAt-30(-300), jumperAt-40(-400), jumperAt-60(-600) } ACCESS read-write STATUS mandatory DESCRIPTION "Selected voltage scale (jumper 0) in DC voltage conversion." ::= { sensorProbeHumidityEntry 28 } sensorProbeHumidityRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { sensorProbeHumidityEntry 29 } sensorProbeHumidityRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { sensorProbeHumidityEntry 30 } sensorProbeHumidityRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highCritical(4), highWarning(3), lowCritical(6), lowWarning(5), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { sensorProbeHumidityEntry 31 } sensorProbeHumidityRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { sensorProbeHumidityEntry 32 } sensorProbeHumidityEmailInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Minimum time between each emial (can be from 0 to 60 minutes)" ::= { sensorProbeHumidityEntry 33 } sensorProbeHumidity4to20mAUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Display unit in DC voltage conversion." ::= { sensorProbeHumidityEntry 34 } sensorProbeHumidityIndexCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Humidity sensor online" ::= { sensorProbeHumidityEntry 35 } sensorProbeHumidityOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Humidity Offset reading" ::= { sensorProbeHumidityEntry 36 } sensorProbeHumiditySirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { sensorProbeHumidityEntry 37 } sensorProbeHumiditySirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { sensorProbeHumidityEntry 38 } sensorProbeHumiditySirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highCritical(4), highWarning(3), lowCritical(6), lowWarning(5), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { sensorProbeHumidityEntry 39 } sensorProbeHumiditySirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { sensorProbeHumidityEntry 40 } sensorProbeHumidityAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Linux Version Only: Acknowledged sensor error and stop notification" ::= { sensorProbeHumidityEntry 41 } sensorProbeHumiditySirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Linux Version Only: Siren delay in seconds before start Alarm." ::= { sensorProbeHumidityEntry 42 } sensorProbeSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorProbeSwitchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { sensorProbeEntry 18 } sensorProbeSwitchEntry OBJECT-TYPE SYNTAX SensorProbeSwitchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorProbeSwitchEntry Table" INDEX { sensorProbeSwitchIndex } ::= { sensorProbeSwitchTable 1 } SensorProbeSwitchEntry ::= SEQUENCE { sensorProbeSwitchDescription DisplayString, sensorProbeSwitchLocation DisplayString, sensorProbeSwitchStatus INTEGER, sensorProbeSwitchOnline INTEGER, sensorProbeSwitchGoOnline INTEGER, sensorProbeSwitchDirection INTEGER, sensorProbeSwitchNormalState INTEGER, sensorProbeSwitchOutputLevel INTEGER, sensorProbeSensorType INTEGER, sensorProbeSwitchEmailTrapLimit INTEGER, sensorProbeSwitchEmailTrapSchedule DisplayString, sensorProbeSwitchEmailTrapInterval INTEGER, sensorProbeSwitchSendNormalTrap INTEGER, sensorProbeSwitchDelayError INTEGER, sensorProbeSwitchDelayNormal INTEGER, sensorProbeSwitchIndex INTEGER, sensorProbeSwitchRelayCycleTime INTEGER, sensorProbeSwitchRelayOnPort INTEGER, sensorProbeSwitchRelayActiveStatus INTEGER, sensorProbeSwitchRelayAction INTEGER, sensorProbeSwitchEmailInterval INTEGER, sensorProbeSwitchRelayOutputVoltStatus INTEGER, sensorProbeSwitchManualRelayCycleTime INTEGER, sensorProbeSwitchManualRelayAction INTEGER, sensorProbeSwitchRelayDescOn DisplayString, sensorProbeSwitchRelayDescOff DisplayString, sensorProbeSwitchIndexCount INTEGER, sensorProbeSwitchSirenCycleTime INTEGER, sensorProbeSwitchSirenOnPort INTEGER, sensorProbeSwitchSirenActiveStatus INTEGER, sensorProbeSwitchSirenAction INTEGER, sensorProbeSwitchAcknowledgement INTEGER, sensorProbeSwitchSirenDelayAlarm INTEGER } sensorProbeSwitchDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorProbeSwitchEntry 1 } sensorProbeSwitchLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this sensor Switch" ::= { sensorProbeSwitchEntry 2 } sensorProbeSwitchStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorProbeSwitchEntry 3 } sensorProbeSwitchOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { sensorProbeSwitchEntry 4 } sensorProbeSwitchGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { sensorProbeSwitchEntry 5 } sensorProbeSwitchDirection OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a switch to input enter 0. To set a switch to output enter 1" ::= { sensorProbeSwitchEntry 6 } sensorProbeSwitchNormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts." ::= { sensorProbeSwitchEntry 7 } sensorProbeSwitchOutputLevel OBJECT-TYPE SYNTAX INTEGER { low(0), high(1) } ACCESS read-write STATUS mandatory DESCRIPTION "An output swith can be set to this level" ::= { sensorProbeSwitchEntry 8 } sensorProbeSensorType OBJECT-TYPE SYNTAX INTEGER { temperature(1), fourTo20mA(2), humidity(3), water(4), atod(5), security(6), airflow(8), siren(9), dryContact(10), voltage(12), relay(13), motion(14) } ACCESS read-write STATUS mandatory DESCRIPTION "Enter the type of this Sensor" ::= { sensorProbeSwitchEntry 9 } sensorProbeSwitchEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { sensorProbeSwitchEntry 11 } sensorProbeSwitchEmailTrapSchedule OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Email/trap limit schedule for this sensor" ::= { sensorProbeSwitchEntry 12 } sensorProbeSwitchEmailTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)" ::= { sensorProbeSwitchEntry 13 } sensorProbeSwitchSendNormalTrap OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email/trap when sensor goes to normal" ::= { sensorProbeSwitchEntry 14 } sensorProbeSwitchDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorProbeSwitchEntry 15 } sensorProbeSwitchDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorProbeSwitchEntry 16 } sensorProbeSwitchIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorProbeSwitchEntry 17 } sensorProbeSwitchRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { sensorProbeSwitchEntry 18 } sensorProbeSwitchRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { sensorProbeSwitchEntry 19 } sensorProbeSwitchRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highCritical(4), highWarning(3), lowCritical(6), lowWarning(5), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { sensorProbeSwitchEntry 20 } sensorProbeSwitchRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { sensorProbeSwitchEntry 21 } sensorProbeSwitchEmailInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Minimum time between each email (can be from 0 to 60 minutes)" ::= { sensorProbeSwitchEntry 22 } sensorProbeSwitchRelayOutputVoltStatus OBJECT-TYPE SYNTAX INTEGER { sensorError(7), noVoltagePresent(10), voltagePresent(11) } ACCESS read-only STATUS mandatory DESCRIPTION "SP Only: The current voltage status of the relay" ::= { sensorProbeSwitchEntry 23 } sensorProbeSwitchManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { sensorProbeSwitchEntry 24 } sensorProbeSwitchManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), cycle-On-Off-On(8), cycle-Off-On-Off(7), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { sensorProbeSwitchEntry 25 } sensorProbeSwitchRelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { sensorProbeSwitchEntry 26 } sensorProbeSwitchRelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { sensorProbeSwitchEntry 27 } sensorProbeSwitchIndexCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Switch sensor online" ::= { sensorProbeSwitchEntry 28 } sensorProbeSwitchSirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { sensorProbeSwitchEntry 29 } sensorProbeSwitchSirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { sensorProbeSwitchEntry 30 } sensorProbeSwitchSirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highCritical(4), highWarning(3), lowCritical(6), lowWarning(5), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { sensorProbeSwitchEntry 31 } sensorProbeSwitchSirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { sensorProbeSwitchEntry 32 } sensorProbeSwitchAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Linux Version Only: Acknowledged sensor error and stop notification" ::= { sensorProbeSwitchEntry 33 } sensorProbeSwitchSirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Linux Version Only: Siren delay in seconds before start Alarm." ::= { sensorProbeSwitchEntry 34 } sensorProbeDebug OBJECT-TYPE SYNTAX INTEGER { on(1), off(0) } ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Turn on or off debug messages" ::= { sensorProbeEntry 20 } sensorProbeTrapResend OBJECT-TYPE SYNTAX INTEGER { on(1), off(0) } ACCESS read-write STATUS mandatory DESCRIPTION "If traps for Warning or Error should be resent. Traps for Normal status are sent once" ::= { sensorProbeEntry 22 } sensorProbeTrapResendInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How often to resend mail or Traps. Enter the number of seconds from 15 to 65535. Mail for WARNING and ERROR are resent at this interval. Traps for Normal status are sent once" ::= { sensorProbeEntry 23 } sensorProbeSendTraps OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Turn on or off the sending of traps" ::= { sensorProbeEntry 24 } sensorProbeTrapDestination OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the trap destination" ::= { sensorProbeEntry 25 } sensorProbeTrapCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The community string of the trap destination" ::= { sensorProbeEntry 26 } sensorProbeDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "If the destination is on another network, enter the IP address of the router" ::= { sensorProbeEntry 27 } sensorProbeSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "If the trap destination uses the default gateway" ::= { sensorProbeEntry 28 } sensorProbeRouteAdd OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Up to 4, Manual additions to the routing table in the form, Network IP Address, Netmask, Gateway IP address" ::= { sensorProbeEntry 29 } sensorProbeSendMail OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Turn on or off the sending of Mail" ::= { sensorProbeEntry 30 } sensorProbeMailRecpt OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The email address of the Recipient" ::= { sensorProbeEntry 31 } sensorProbeMailFrom OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The email address of the Sender" ::= { sensorProbeEntry 32 } sensorProbeMailSMTP OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The Address of the SMTP server" ::= { sensorProbeEntry 33 } sensorProbeMailJpgInline OBJECT-TYPE SYNTAX INTEGER { inline(1), link(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If the jpg for this event is sent as an http link or is included with mail as an attachment" ::= { sensorProbeEntry 34 } sensorProbeMailResendInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How often to resend mail or Traps. Enter the number of seconds from 10 to 60. Mail for WARNING and ERROR are resent at this interval. Mail for Normal status are sent once" ::= { sensorProbeEntry 36 } sensorProbeMailMaxResend OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of times to resend mail. If set to 0 only send once. The maximum value is 5" ::= { sensorProbeEntry 37 } sensorProbeMailLastStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The status of the most recent attempt to send an email" ::= { sensorProbeEntry 39 } sensorProbeSupportMailRcpt OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP8L only: E-Mail address of support" ::= { sensorProbeEntry 40 } sensorProbeCameraServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorProbeCameraServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "CP8 Only: This table contains the Camera Server features, This allows the sensorProbe to connect to a sensorProbe" ::= { sensorProbeEntry 42 } sensorProbeCameraServerEntry OBJECT-TYPE SYNTAX SensorProbeCameraServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorProbeCameraServerEntry Table" INDEX { sensorProbeCameraServerIndex } ::= { sensorProbeCameraServerTable 1 } SensorProbeCameraServerEntry ::= SEQUENCE { sensorProbeCameraServerClientOnline INTEGER, sensorProbeCameraServerClientGoOnline INTEGER, sensorProbeCameraServerClientIP IpAddress, sensorProbeCameraServerClientSetPassword DisplayString, sensorProbeCameraServerIndex INTEGER, sensorProbeJavaTimeOut INTEGER, sensorProbeJpegQualityFactor INTEGER } sensorProbeCameraServerClientOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Client is currently online" ::= { sensorProbeCameraServerEntry 1 } sensorProbeCameraServerClientGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put this Client online enter a 1, to take offline enter a 2" ::= { sensorProbeCameraServerEntry 2 } sensorProbeCameraServerClientIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the sensorProbe, used to send snmp keep alive messages" ::= { sensorProbeCameraServerEntry 3 } sensorProbeCameraServerClientSetPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The Set Password for the snmp keep alive messages sent to the sensorProbes" ::= { sensorProbeCameraServerEntry 4 } sensorProbeCameraServerIndex OBJECT-TYPE SYNTAX INTEGER (0..9) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Camera table" ::= { sensorProbeCameraServerEntry 5 } sensorProbeJavaTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Timeout in minutes for Java client" ::= { sensorProbeCameraServerEntry 6 } sensorProbeJpegQualityFactor OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "Quality factor of jpeg image" ::= { sensorProbeCameraServerEntry 7 } sensorProbeTrapMailPollInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: How often the sensor thresholds are tested before sending traps or mail. This can vary from 3 to 15 seconds" ::= { sensorProbeEntry 50 } sensorProbeSendTestMail OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Send out an email test message" ::= { sensorProbeEntry 51 } sensorProbeLastSystemError OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A text string containing the description of the last system error" ::= { sensorProbeEntry 52 } sensorProbeDataCollectionPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of minutes between collections of the data logger. This can vary from 1 to 60 minutes" ::= { sensorProbeEntry 53 } sensorProbeMailTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds to wait for a timeout while sending email This can vary from 10 to 30 seconds" ::= { sensorProbeEntry 54 } sensorProbeAutoSense OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable Auto-sense feature" ::= { sensorProbeEntry 55 } sensorProbeChecksum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SP Only: The Flash Checksum, computed dynamically whenever this object is read" ::= { sensorProbeEntry 56 } sensorProbeUsePassword OBJECT-TYPE SYNTAX INTEGER { doNotUsePassword(1), usePassword(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether or not the set and get community are used to check for access rights" ::= { sensorProbeEntry 57 } sensorProbeDisplayLogo OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or Disable the display of the logo" ::= { sensorProbeEntry 59 } sensorProbeTrapType OBJECT-TYPE SYNTAX INTEGER { specificTypeTrap(1), generalTypeTrap(2), bothTypeTraps(3), statusTypeTraps(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Whether to generate a trap that covers all sensors, a specific trap for each sensor, or both types of traps" ::= { sensorProbeEntry 60 } sensorProbeMailCC OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The email address of the CC" ::= { sensorProbeEntry 61 } sensorProbeAllowIPChange OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This disables the changing of the IP address. The default is to enable changing the IP address" ::= { sensorProbeEntry 62 } sensorProbeTimeOfDay OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The time of day in the format day/month/year hour(1-24):minutes:seconds for example 23/10/02 12:45:06" ::= { sensorProbeEntry 65 } sensorProbeEnableSysLog OBJECT-TYPE SYNTAX INTEGER { enableLogToFlash(1), enableLogToNetAndFlash(2), disable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables sysLog Messages,including logging to the Net. The Destination IP of the net messages is the same as the source IP of the sender of this command" ::= { sensorProbeEntry 66 } sensorProbeReadSysLog OBJECT-TYPE SYNTAX INTEGER { lastMessage(1), allMessages(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Return the sysLog Message in the snmp PDU and if enableLogToNetAndFlash in sensorProbeEnableSysLog, also send in debug message format, A Write of a 2 will return all of the messages in debug format" ::= { sensorProbeEntry 67 } sensorProbeClearSysLog OBJECT-TYPE SYNTAX INTEGER { allMessages(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Delete all entries in the sys log" ::= { sensorProbeEntry 68 } sensorProbeSyslogDestIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of the Syslog server. Note: This must be in dotted decimal form" ::= { sensorProbeEntry 69 } sensorProbeSyslogPort OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The Port Number of the Syslog server." ::= { sensorProbeEntry 70 } sensorProbeSetSyslogMsgPrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The Prefix message of the Syslog message" ::= { sensorProbeEntry 71 } -- -- sensorProbeEntry 72 is reserved for sensorProbeLanFullDuplex ( SP Only ) -- -- -- sensorProbeEntry 73 is reserved for sensorProbeExpectedMicrocodeCRC ( SP Only ) -- -- -- sensorProbeEntry 74 is reserved for sensorProbeExpectedMicrocodeLength ( SP Only ) -- -- -- sensorProbeEntry 75 is reserved for sensorProbeActualMicrocodeCRC ( SP Only ) -- -- -- sensorProbeEntry 76 is reserved for sensorProbeExpectedBootCRC ( SP Only ) -- -- -- sensorProbeEntry 77 is reserved for sensorProbeActualBootCRC ( SP Only ) -- -- -- sensorProbeEntry 78 is reserved for sensorProbeBootVersion ( SP Only ) -- -- -- sensorProbeEntry 80 is reserved for sensorProbeAdcCalibrate -- sensorProbeTimeZone OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "System time zone" ::= { sensorProbeEntry 81 } -- -- sensorProbeEntry 82 is reserved for sensorProbeExtraDryContactEnable ( SP Only ) -- sensorProbeMegaVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Version number of mega board" ::= { sensorProbeEntry 83 } sensorProbeNtpMode OBJECT-TYPE SYNTAX INTEGER { notUse(0), oneTime(1), onSystemStartUp(2), onceAMounth(3), onceAWeek(4), onceADay(5), onceAnHour(6), continuous(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode to synchronous with ntp server" ::= { sensorProbeEntry 84 } sensorProbeNtpServer OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "NTP server which this machine synchronous with" ::= { sensorProbeEntry 85 } -- -- sensorProbeEntry 86 is reserved for SensorProbeModel string which is used internaly (AKCP). -- sensorProbeSMTPAuth OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables the SMTP authentication" ::= { sensorProbeEntry 87 } sensorProbeSMTPLogin OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The username used to login into SMTP server" ::= { sensorProbeEntry 88 } sensorProbeSMTPPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The password used to login into SMTP server" ::= { sensorProbeEntry 89 } sensorProbeDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the DNS server" ::= { sensorProbeEntry 90 } sensorProbeAltWebPort OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The alternative for a port number 80 used to access the web interface" ::= { sensorProbeEntry 91 } sensorProbeNumberOfSensorPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of sensor ports(regardless of their current state)" ::= { sensorProbeEntry 92 } sensorProbeSendTrapsAlive OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "On or off send keep alive traps." ::= { sensorProbeEntry 93 } sensorProbeTrapReIntervalAlive OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Time between each keep alive trap." ::= { sensorProbeEntry 94 } sensorProbeUseCamera OBJECT-TYPE SYNTAX INTEGER { on(1), off(0) } ACCESS read-write STATUS mandatory DESCRIPTION "On or off camera." ::= { sensorProbeEntry 95 } sensorProbeAdcCalibratePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Calibrate value for analog sensor." ::= { sensorProbeEntry 96 } -- -- sensorProbeEntry 97 is reseverd for future using with Linux version (AKCP). -- sensorProbeMailSubject OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Email Subject." ::= { sensorProbeEntry 98 } sensorProbeSnmpPort OBJECT-TYPE SYNTAX Gauge ACCESS write-only STATUS mandatory DESCRIPTION "SP Only: Port number used to access snmp" ::= { sensorProbeEntry 99 } sensorProbeSnmpTrapPort OBJECT-TYPE SYNTAX Gauge ACCESS write-only STATUS mandatory DESCRIPTION "SP Only: Port number used to access trap snmp" ::= { sensorProbeEntry 100 } sensorProbeSnmpIndexingMode OBJECT-TYPE SYNTAX INTEGER { index0(0), index1(1) } ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Snmp table index starting from 0 or 1 " ::= { sensorProbeEntry 101 } -- -- sensorProbeEntry 102 is reserved for sensorProbeSensorSummary -- -- -- Varbinds used in TRAP Definitions -- sensorProbeTraps OBJECT IDENTIFIER ::= { sensorProbe 7 } spSensorStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7), turnOn(8), turnOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current integer status of the sensor causing this trap to be sent" ::= { sensorProbeTraps 1 } spSensorValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current integer value of the sensor causing this trap to be sent" ::= { sensorProbeTraps 2 } spSensorLevelExceeded OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The integer level that was exceeded causing this trap to be sent" ::= { sensorProbeTraps 3 } spSensorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The integer index of the sensor causing this trap to be sent" ::= { sensorProbeTraps 4 } spSensorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the sensor causing this trap to be sent" ::= { sensorProbeTraps 5 } spSensorDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the sensor causing this trap to be sent" ::= { sensorProbeTraps 6 } spSensorProbeKeepAlive OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Keep alive trap to be sent" ::= { sensorProbeTraps 7 } spSensorType OBJECT-TYPE SYNTAX INTEGER { temperature(1), fourTo20mA(2), humidity(3), water(4), atod(5), security(6), airflow(8), dryContact(10), voltage(12), relay(13), motion(14) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of this sensor" ::= { sensorProbeTraps 8 } -- TRAP Definitions spUnknownStatus TRAP-TYPE ENTERPRISE sensorProbe DESCRIPTION "sensorProbe status went to Unknown" --#TYPE "sensorProbe Unknown Status" --#SEVERITY INFORMATIONAL ::= 0 spNormalStatus TRAP-TYPE ENTERPRISE sensorProbe DESCRIPTION "sensorProbe status is Normal" --#TYPE "sensorProbe Normal Status" --#SEVERITY INFORMATIONAL ::= 1 spWarningStatus TRAP-TYPE ENTERPRISE sensorProbe DESCRIPTION "sensorProbe status went to Warning" --#TYPE "sensorProbe Warning Status" --#SEVERITY MINOR ::= 2 spCriticalStatus TRAP-TYPE ENTERPRISE sensorProbe DESCRIPTION "sensorProbe status went to Critical" --#TYPE "sensorProbe Critical Status" --#SEVERITY MAJOR ::= 3 spDownStatus TRAP-TYPE ENTERPRISE sensorProbe DESCRIPTION "sensorProbe status went to Disabled" --#TYPE "sensorProbe Down Status" --#SEVERITY MINOR ::= 4 spKeepAliveTrap TRAP-TYPE ENTERPRISE sensorProbe DESCRIPTION "sensorProbe send keep alive trap." --#SEVERITY INFORMATIONAL ::= 5 -- sensorProbeTrapType = generalTypeTrap(2) spTemperatureStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 10 spAnalogueStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 20 spSwitchStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 30 spPowerMonitorStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Power Monitor sensor trap" --#SEVERITY MAJOR ::= 40 -- sensorProbeTrapType = statusTypeTraps(4) spSenUnknownStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "sensorProbe sensor status went to Unknown" --#TYPE "sensorProbe Unknown Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY MAJOR --#TIMEINDEX 4 ::= 51 spSenNormalStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "sensorProbe sensor status is Normal" --#TYPE "sensorProbe Normal Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 ::= 52 spSenWarningStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "sensorProbe sensor status went to Warning" --#TYPE "sensorProbe Warning Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY MINOR --#TIMEINDEX 4 ::= 53 spSenCriticalStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "sensorProbe sensor status went to Critical" --#TYPE "sensorProbe Critical Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY MAJOR --#TIMEINDEX 4 ::= 54 spSenDownStatus TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "sensorProbe sensor status went to Disabled" --#TYPE "sensorProbe Down Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 ::= 55 -- sensorProbeTrapType = specificTypeTrap(1) spTemperature1Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 101 spTemperature2Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 102 spTemperature3Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 103 spTemperature4Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 104 spTemperature5Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 105 spTemperature6Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 106 spTemperature7Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 107 spTemperature8Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 108 spAnalogue1Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 201 spAnalogue2Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 202 spAnalogue3Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 203 spAnalogue4Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 204 spAnalogue5Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 205 spAnalogue6Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 206 spAnalogue7Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 207 spAnalogue8Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 208 spSwitch1Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 301 spSwitch2Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 302 spSwitch3Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 303 spSwitch4Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 304 spSwitch5Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 305 spSwitch6Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 306 spSwitch7Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 307 spSwitch8Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 308 spSwitch9Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 309 spSwitch10Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 310 spSwitch11Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 311 spSwitch12Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 312 spSwitch13Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 313 spSwitch14Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 314 spSwitch15Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 315 spSwitch16Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 316 spSwitch17Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 317 spSwitch18Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 318 spSwitch19Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 319 spSwitch20Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 320 spSwitch21Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 321 spSwitch22Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 322 spSwitch23Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 323 spSwitch24Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 324 spSwitch25Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 325 spSwitch26Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 326 spSwitch27Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 327 spSwitch28Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 328 spSwitch29Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 329 spSwitch30Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 330 spSwitch31Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 331 spSwitch32Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 332 spSwitch33Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 333 spSwitch34Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 334 spSwitch35Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 335 spSwitch36Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 336 spSwitch37Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 337 spSwitch38Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 338 spSwitch39Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 339 spSwitch40Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 340 spSwitch41Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 341 spSwitch42Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 342 spSwitch43Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 343 spSwitch44Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 344 spSwitch45Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 345 spSwitch46Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 346 spSwitch47Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 347 spSwitch48Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 348 spSwitch49Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 349 spSwitch50Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 350 spSwitch51Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 351 spSwitch52Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 352 spSwitch53Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 353 spSwitch54Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 354 spSwitch55Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 355 spSwitch56Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 356 spSwitch57Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 357 spSwitch58Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 358 spSwitch59Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 359 spSwitch60Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 360 spSwitch61Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 361 spSwitch62Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 362 spSwitch63Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 363 spSwitch64Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 364 spSwitch65Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 365 spSwitch66Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 366 spSwitch67Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 367 spSwitch68Status TRAP-TYPE ENTERPRISE sensorProbe VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 368 END