4-20 mAmp Sensor

USD $150.00

- +

4-20mAmp Converter

The 4-20mA converter is used to integrate the sensorProbe with a 4-20mA sensor

4-20mA technology is used to communicate analog signals over long distances where electrical interference is a problem.

  • Powered by the base unit

Additional information

Option

4-20 mAmp Sensor

The 4-20 mAmp signal converter is used to integrate the sensorProbe with a 4-20 mAmp transmitter. 4-20 mAmp technology is used to communicate analog signals over long distances where electrical interference is a problem. This solution is often used in the process control industry to collect the analog values from a wide array of remote sensors.

Current signals are much less susceptible to noise than voltage signals. A voltage signal can be converted to current and then broadcast over a long distance before it is converted back to voltage and read by the sensorProbe.

4-20 mAmp transmitters are common in the industry for use with high quality sensors. With the 4-20 mAmp converter these sensors can now be integrated into the sensorProbe enhancing their value with the addition of graphing, web interface, email interface, thresholds, and limits.

Specifications

Specifications

Measuring Specifications  
Input 2 pin Phoenix connector : 4-20mA Iin(+) and Iin(-) for current loop
Output Voltage Range +0.4 V to +2.0 V
Linearity ± 0.09 % Full Scale, Maximum
Accuracy ± 0.15% Full Scale (± 0.3% Full Scale, Maximum)
Status Indication LED indication for current detection
LED indication for power
Electrical no galvanic isolation
Components Manufactured using highly integrated, low power surface mount technology to ensure long term reliability.
Operating Environment Temperature : Min. -35° C – Max.80° C
Humidity: Min. 20% – Max. 80% (Non-Condensing)
   
Interface  
Communications cable RJ-45 jack to sensor using UTP CAT5e/6 cable
Power source Powered by the controller unit. No additional power needed
Power Consumption Typical 120 mWatt, 24mA
Maximum Cable Length  The 4-20mA sensor Adaptor can be extended from the RJ-45 Intelligent Sensor ports on the base units up to 50 feet, or 15 meters using standard CAT5/6 LAN cable
Dimensions 65(W) x 62(H) x 15(D) mm
Mounting DIN rail mounting
Screw mounting
Sensor count 1

Features

  • Converts current levels from 4 – 20 mA to 0.8 – 4.0 V voltage levels
  • Maximum linearity of ± 0.09%
  • Maximum accuracy of ± 0.15%
  • Operates from a single +5 V DC Power Supply which is powered by the sensorProbe
  • Fully Rated Over the -40°C to 85°C Industrial Temperature Range
  • 2 LED show status of the current loop and the power supply
  • Up to two I V converters per sensorProbe2, 8 per sensorProbe8

Video Presentation

3D View


View Separately